FF-P-110J
TABLE I. Classification of defects.
Requirement
Classification
Defects
paragraph
Critical:
01
Combination setting can be changed without
3.4
knowledge of existing combination.
02
Does not disperse or scramble combination setting as 3.4
specified.
03
Shackle can be locked out in open position.
3.4
04
Dialing tolerance not as specified. Less than 30,000 3.4.1
different independent combinations.
Major:
101
Material not as specified.
3.3.1
102
Clearance permits insertion of probes.
3.5
103
Dial markings not as specified.
3.7
104
Combination change device not corrosion-resistant
3.10
as specified.
105
Combination change device not marked as specified.
3.10
106
Broken, split, fractured, or cracked part.
3.15
107
Functioning component is inoperative or will not
3.15
operate as intended.
Minor:
201
Lubrication not as specified.
3.11
202
Finish not as specified.
3.12
203
Marking on back not as specified.
3.13.1
204
Marking incomplete or incorrect.
3.13.1
205
Marking method not as specified.
3.13.1.1
206
Shackle and case not serialized as specified.
3.13.2.1 and
3.13.2.2
207
Parts or components not free from burrs, splinters, or 3.14
rough edges.
208
Combination setting or operation instructions
3.15
missing or incomplete.
4.3.1.1 Delivery. As specified (see 3.1.1 and 6.2), bid samples shall be delivered to the test
facility, transportation prepaid, furnished at no cost to the Government. Samples shall be plainly
identified by securely attached durable tags, marked as follows:
Bid Sample for Test
Padlock, changeable combination
(Class Type)
Fed. Spec. FF-P-110J
Date of manufacture: (mm/yy)
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business