FF-P-110J
TABLE II. Test Schedule.
Bid
First
Quality
Test
Requirement
samples
article
conformance
Test
paragraph
paragraph
1
2
3
4
5
6
X
X
3.5, 3.8
4.6.3.1
Manipulation resistance.
X
X
3.5, 3.8
4.6.3.2
Surreptitious resistance.
X
X
3.9, 3.9.1
Radiographic opening resistance. 4.6.3.3
X
3.5, 3.8
X
4.6.3.4
Direct tension resistance.
X
X
3.5, 3.8
X
4.6.3.5
Jar with tension resistance.
X
3.5, 3.8
X
4.6.3.6
Jar without tension resistance.
X
3.5, 3.8
4.6.3.7
X
Shackle and lock strength.
X
X
3.5, 3.8
4.6.3.8
X
Drop resistance.
X
X
3.2
4.6.3.9
X
High temperature operations.
X
X
3.2
4.6.3.10
Low temperature operations.
X
X
X
3.2, 3.12
4.6.3.11
High humidity.
X
X
3.3.1
4.6.3.12
Heat resistance.
X
3.4.1, 3.11
X
4.6.3.13
Cycle test for wear and
X
lubricant.
4.6.3.2 Surreptitious attack test. There shall be no limit on the number of surreptitious attacks
attempted and each attack may be applied for the full specified time. The best method or
combination of methods may be applied for the full net working time. The net working time will
include time expended for any masking or repair of damage to the lock that may become
necessary to obliterate evidence of penetration. Any repairs necessary to obliterate or mask
evidence of attack shall be made without substitution of parts. There shall be no limitations on
the time required for exploration and preparation for the test. The tools and devices used in the
test will be limited to those powered by hand. The tools shall be capable of being carried in a case
not exceeding 1.5 ft3 (0.04245 m3) in volume and 9 inches (228.6 mm) in thickness, and shall not
exceed a total of 25 lbs (11.34 kg) (exclusive of weight of case). Heat above 300 °F (149 °C),
such as that from a blowtorch or an electric arc, shall not be used. The padlock shall resist
opening by surreptitious attack for the period of time specified in 3.8.